Monte Carlo Fan Company Crystoria Installation Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 6
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
© 2011 Monte Carlo Fan Company
2/11/2012
5
1.Check main and branch circuit fuses or circuit break ers.
2.Check line wire connections to fan and switch wire connections in switch housing.
CAUTION: Make sure main power is turned off.
1.Check to make sure all screws in motor housing are snug (not o ver tightened).
2.Check to make sure wire nut connectors in switch housing are not r attling against each other
or against the interior wall of the switch housing.
CAUTION: Make sure main power is turned off before entering switch housing.
3.Some fan motors are sensitive to signals from Solid State v ariable speed controls.
DO NOT USE a Solid State variable speed control.
4.Allow "break-in" period of 24 hours. Most noises associated with a new fan will disappear
after this period.
1.All blades are weighed and grouped b y weight. Natural woods vary in density which could
cause the fan to wobble ev en though all blades are weight -matched. The following procedures
should eliminate most of the wobble. Check for wobble after each step .
2.Make sure that the ridge of the canop y engages the notch in the downrod ball.
3.Check that all blades are screwed firmly into blade holders.
4.Check that all blade holders are tightened securely to motor .
5.Make sure that canopy and mounting bracket are tightened securely to ceiling junction bo x
and junction box is mounted firmly to ceiling joist.
6.If blade wobble is still noticeable, interchanging two adjacent (side b y side) blades can redis -
tribute the weight and possibly result in smoother oper ation.
1.Check wire from fan to mak e sure it is connected to hot wire from house.
2.Check for loose or disconnected wires in fan switch housing.
3.Check for loose or disconnected wires in light kit.
4.Check for faulty light bulbs.
CAUTION: Make sure main power is turned off before entering switch housing.
2. If fan sounds noisy:
1. If fan does not start:
3. If fan wobbles:
4. If light does not work:
Trouble Shooting
If you have difficulty operating your new ceiling fan, it ma y be the result of incorrect assembly, installation, or wiring. In
some cases, these installation errors ma y be mistaken for defects. If you experience any faults, please check this Trouble
Shooting Chart. If a problem cannot be remedied, or y ou are experiencing difficulty in installation, please call our
Customer Service Center at the number printed on y our parts list insert sheet.
Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
TROUBLE SUGGESTED REMEDY
Page view 4
1 2 3 4 5 6

Comments to this Manuals

No comments